Wall Mount Adapter Help

Accessory Help

Lot Number -
Model -

Wall Mount Adapter (WMA) - Help & Support

← View All 414 Monitors

The Wall Mount Adapter (WMA) allows any 414-series monitor-controller to be mounted directly to a wall surface instead of panel-mounting. The adapter plate attaches to the enclosure's rear cover using the provided hardware, and the assembly is then secured to the wall through four mounting holes.

Compatibility
All 414-Series
Mounting Type
Wall Surface
Hardware Included
#4-40 Screws, Nuts, Washers
Wall Fasteners
User-Supplied
Note: Complete all wall mounting steps prior to performing any electrical wiring. Refer to the unit's Installation & Operation Manual for all wiring instructions.

Troubleshooting

The adapter plate does not align with the back cover

If the adapter plate holes do not line up with the back cover:

  • Verify you drilled at all 4 guide positions - The depressions on the inside of the back cover indicate the correct drill locations.
  • Check drill bit size - Use a 7/64" drill bit as specified.
  • Confirm WMA compatibility - The WMA is designed for all 414-series enclosures. Contact support if you have a non-standard unit.
The enclosure does not reattach securely after wall mounting

If the enclosure is loose or difficult to reattach:

  • Ensure the back cover is flush against the wall - The adapter plate should sit flat against the wall surface with no gaps.
  • Check for interference - Make sure wiring is routed cleanly and does not prevent the enclosure from seating properly.
  • Verify captive screws - The 4 captive screws should thread smoothly into the enclosure.
Need help? Our support team is ready to assist with installation, troubleshooting, or replacement parts. Have your model and lot number ready if available.
orders@hydrocheck.com

Manuals & Instructions

WMA Installation Instructions (PDF)

Complete installation instructions for the WMA Wall Mount Adapter.

Installation

Remove the Enclosure Back Cover Prior to electrical wiring, remove the back cover of the enclosure by unscrewing the 4 screws. The screws are captive and cannot be completely removed from the rear cover.
Drill Mounting Holes in the Back Cover Locate the 4 depressions in the plastic on the inside of the back cover. Using a 7/64" drill bit, drill through the back cover at all 4 positions.
Attach the Adapter Plate Assemble the Wall Mount Adapter to the rear cover using the provided #4-40 screws, nuts, and washers.
Mount to the Wall Mount the adapter and back-cover assembly to the wall using appropriate fasteners for the wall material.
Reassemble the Enclosure Complete all electrical wiring per the unit's Installation & Operation Manual. Reattach the enclosure to the back cover using the 4 captive screws.

For detailed wiring diagrams and terminal assignments, see the unit's User Manual (PDF).

Frequently Asked Questions

Which 414-series monitors is the WMA compatible with?

The WMA is compatible with all 414-series monitor-controllers, including the 414R, 414C, and 414TDS, across all voltage configurations and output models.

What tools do I need for installation?

You will need a 7/64" drill bit and a screwdriver for the captive enclosure screws. You will also need fasteners appropriate for your wall material.

Are wall fasteners included?

No. The WMA includes hardware for attaching the adapter plate to the enclosure back cover. Wall fasteners must be supplied by the installer.

Can I perform wiring before mounting to the wall?

Hydro-Check recommends completing all wall mounting steps before performing any electrical wiring.

Can I convert back to panel mounting later?

Yes. The WMA is a reversible accessory. Remove the enclosure from the wall, detach the adapter plate from the rear cover, and the unit can be panel-mounted again.

Does the WMA work with the 414-RMA Remote Alarm?

Yes. The WMA is fully compatible with the 414-RMA Remote Alarm Module and all other 414-series accessories.

Documentation

WMA Installation Instructions PDF
Certificate of Conformance
Lot Number - | Model: WMA Wall Mount Adapter

This page is ready for the WMA certificate family. When no QR code is scanned, only the general WMA certificate is shown. When opened with scan context, the batch-specific block is shown as well.

General Certificate

Download a standard Certificate of Conformance for WMA Wall Mount Adapters.

Batch-Specific Certificate

Certificate with traceability and compliance data for your specific lot number.

Contact Us

Contact Us
First
Last

For complete product information, visit the 414 Monitor Help page or contact orders@hydrocheck.com.

1996 - 2026

Celebrating 30 Years of Cleaner Water

© 2026 Hydro-Check Systems, Inc. All Rights Reserved.

Copyright © 2026 Professional Water Quality Management Instruments, All Rights Reserved.

Return/Refund Policy